Investors Architectural New Zealand Open an account Get a quote
BUILDING PRODUCTS RANGE

Building Products

Big River Group supplies a broad range of building products that complement our core timber and panel ranges – from internal and external doors to insulation, builders hardware and NCC-compliant fire doors. These are the products that complete a build: the items specifiers and site managers need alongside structural framing, flooring and cladding.

All building products are available for trade pickup or delivery from our national location network, giving builders a single supplier for the full material schedule rather than splitting orders across multiple vendors.

Showing 18 products

Quick Contact

    Prefer to talk? Call 1300 88 1958 Want to give us more information? Use our full enquiry form →

    By submitting this form you agree to our Privacy Policy.

    Innova Ceramic Tile Underlay

    Innova Ceramic Tile Underlay

    eramic Tile Floor Underlay is a specially formulated fibre cement sheet, designed as a stable substrate for slate and ceramic floor tiles.

    Durable Termite Resistant
    Innova Compressed Flooring

    Innova Compressed Flooring

    Compressed flooring is a premium substrate, primarily used in commercial applications for high-load areas.

    Termite Resistant Durable

    MaxiFloor Structural Flooring

    Engineered flooring system for residential and commercial builds.

    Multi-storey floor systems

    Fire Rated Acoustic Rated Australian Made BAL-FZ Non-Combustible Fire Resistant

    T&G Ply - Flooring & Roofing

    Armourply T&G Flooring: T & G Structural ply flooring and roofing is ideal for residential applications, but is also...

    Floor substrate and finishing

    EWPAA Super E0 Emission F14 Stress Grade F11 Stress Grade Australian Made

    Uni-Curve

    Flexible EPS panels for curved walls and architectural features.

    Curved Walls & Architectural Features

    CodeMark Accredited Flexible for Curves Custom Sizes Available No Laminating Layers
    Laminex EnduraFloor General Purpose particleboard flooring - green tongue 19mm, beige tongue 22mm and brown tongue 25mm

    Yellow Tongue Particleboard Flooring

    Structural particleboard flooring - the Laminex General Purpose range in 19mm, 22mm and 25mm, Australian made.

    Floor Substrate & Finishing

    Moisture Resistant Australian Made
    GUIDE

    How to Choose the Right Building Products

    Doors – Internal, External and Fire-Rated

    Door selection starts with application. Standard internal doors are typically hollow-core for weight and cost efficiency, while external entry doors require solid-core construction with weather seals and hardware rated for exposure. Fire doors are a compliance item – the NCC requires fire-resistant doorsets tested to AS 1905.1 in any wall with a required Fire Resistance Level. Fire doors must be supplied, installed and maintained as a complete certified doorset including frame, seals, hinges and closer. Mixing components from different manufacturers voids the certification.

    Insulation and NCC Energy Compliance

    The NCC 2022 raised minimum thermal performance to 7 stars under NatHERS, which has increased R-value requirements across all climate zones. Ceiling insulation in most zones now needs R5.0 or higher, and wall insulation requirements have moved to R2.5–R2.7 for standard framed construction. Insulation type matters too – glasswool batts suit most wall and ceiling applications, while rigid board products are required for slab edge and underfloor situations. Your Big River location team can advise on the R-values required for your specific climate zone and construction type.

    Builders Hardware and Door Furniture

    Hardware quality directly affects long-term building performance. Hinges, handles, locks and closers are high-use components – undersized or low-grade hardware leads to sagging doors, worn finishes and callback costs. For door hardware on fire-rated doorsets, every component must be tested as part of the certified assembly. Specify hardware from the doorset manufacturer’s approved schedule rather than substituting aftermarket fittings.

    Sourcing Building Products Through a Single Supplier

    Splitting material orders across multiple suppliers creates procurement overhead, delivery coordination problems and increased risk of site delays. Big River’s building products range is stocked alongside our structural timber, plywood, cladding and flooring – so a single order and a single delivery covers the full material schedule. Talk to your local location team about project-based supply packages.

    FAQ

    Frequently Asked Questions

    What fire rating do internal doors need to comply with the NCC?

    The NCC requires fire doors in walls with a Fire Resistance Level to comply with AS 1905.1. The standard FRL for most fire doors is –/60/30 (60 minutes integrity, 30 minutes insulation). Fire doors in fire walls may require higher ratings. The door must be tested and certified as a complete doorset – leaf, frame, seals and hardware – not assembled from separate components.

    What R-value insulation do I need for a new home in Australia?

    R-value requirements depend on your NCC climate zone. Under the NCC 2022 7-star provisions, most zones require ceiling insulation of R5.0 or above and wall insulation of R2.5–R2.7 for standard framed construction. Slab edge insulation is mandatory in climate zones 7 and 8, and for any slab with in-slab heating. Contact your Big River location for zone-specific guidance.

    What is the difference between a fire door and a smoke door?

    Fire doors are tested to AS 1905.1 and resist the passage of fire for a rated period, measured by integrity and insulation criteria. Smoke doors are designed to resist the passage of smoke at 200°C for 30 minutes. The NCC may require both in the same building depending on the fire compartment design. Smoke door leaves must swing in both directions or in the direction of travel and cannot be sliding doors or roller shutters.

    Can I buy building supplies from a Big River location without a trade account?

    Big River locations serve both trade account holders and general customers. A trade account provides benefits including competitive pricing, credit terms, a dedicated account manager and streamlined ordering. Contact your nearest location or call 1300 88 1958 to discuss account options.

    Why does hardware on fire doors need to be from the same certified doorset?

    Under AS 1905.1, a fire door is tested and certified as a complete assembly – the leaf, frame, seals, hinges, closer and lock must all be part of the tested configuration. Substituting hardware that was not included in the original test invalidates the certification, even if the replacement components appear identical. Always specify hardware from the doorset manufacturer’s approved schedule.

    EXPLORE

    Related Product Categories

    Frame & Truss

    Structural framing timber, LVL, and engineered products for wall frames, roof trusses, and floor framing in residential and commercial construction.

    Explore →

    Interior Fixtures

    Skirting boards, architraves, door jambs, and finishing timber for residential and commercial fix-out projects.

    Explore →

    Cladding

    External cladding products for residential and commercial builds - fibre cement, timber, and composite options from Australia's leading brands.

    Explore →

    Structural Timber

    Framing timber, LVL beams, and timber mouldings for residential, commercial, and industrial construction across Australia.

    Explore →
    FIND US

    Visit Your Local Big River Location

    Find specialist building products and expert advice at your nearest Big River Location.

    Australian Made
    AS/NZS Compliant
    ASX Listed
    25 Locations
    130+ Years
    Menu